Technical Data | CW-FS | Perimeter Barriers and Firestops for Curtain Walling | Façades | Products | Siderise

Siderise CW-FS | Perimeter Barriers and Firestops for Curtain Walling – Technical Data

Version: 2.04 - Release Date: October 2023

Application

Siderise CW-FS perimeter barrier and fire stop systems offer an extensive range of solutions for fire stop, and acoustic barrier requirements in all curtain wall applications. The CW Systems also resist the passage of smoke and hot gases. CW systems may also be used in fire stop and cavity barrier applications in conjunction with weathertight façade systems such as precast concrete cladding and architectural cladding panels.
 
The primary function of the CW system is to maintain continuity of fire resistance by sealing the void between the compartment floors or walls and the external curtain wall both horizontally and vertically.
 
Apart from being simple and quick to install CW systems’ unique product construction also provides the ability to accommodate movement for the life of the building.

Product Description

Siderise CW systems are manufactured using a unique method that provides resilient lateral compression. This facilitates installation, ensuring the requisite tight fit and enhancing the fire integrity of the product.
 
Throughout the range, the materials comprise a one-piece product with a pre-compressed non-combustible stonewool core. The products also have integral aluminium foil facings to provide an overall Class A1 rating (to EN 13501-1).
 
The systems can offer tested fire resistance options ranging from 30 mins to 3 hours (3 hours to EN 1364-4 only) and can accommodate void widths up to 600mm (600mm voids to EN 1366-4 only) . In addition to providing an effective seal against the passage of smoke and fire, the products are also acoustically absorptive.

Standard Systems
The materials can be either supplied as pre-cut units to suit a specified void size or in sheet form for cutting on site.
 
Standard sheet products are supplied 1200 x 1200 mm which may prove beneficial when the actual void size is not known or where it varies significantly. Please note that when ordered in sheet form, the requisite quantity of fixing brackets needs to be purchased separately.
 
Pre-cut strips are available in 1mm increments of width to suit the cavity size to provide a tight compressive fit within the–void - Please see Tables 2-4 regarding fit type. Each pre-cut CW unit is supplied with appropriate fixing brackets as part of the system.
 
The standard fixing brackets are supplied in galvanized mild steel in a flat form that is complete with a pre-notched facility for folding on site. Brackets are also available in stainless steel.
 
All hole positions are to be drilled to suit the varying site conditions. Different size brackets are available according to the cavity size – please see Tables 2-4.
 
All fixing brackets are to be mechanically secured to the substructure with suitable non-combustible fixings.

Fire Performance

Reaction to fire

Siderise CW-FS perimeter barriers and fire stops have third party certification with Intertek and are classified as A1 to EN 13501-1. Please see Table 1 for further information.

Table 1 : Reaction to Fire Performance

Certificate Number WHI20-32944302 (US) & WHI-09/02-22-000001-02 (UK) 
Thickness Range 50-175mm 
Substrates Mechanically fixed to gypsum or any other A1 or A2-s1,d0 substrate 
Joints With or without joints 
Resistance to fire
Siderise CW-FS systems have been tested to both EN 1364-4 and EN 1366-4. CW-FS perimeter barrier and fire stops maintained integrity (E) and insulation (I) requirements as detailed in Tables 2-4. The tables summarise the void sizes, fire resistance performance, and provide 3rd party certification details where applicable.
 
Siderise CW systems provide continuity of fire resistance across the void when aligned with fire-rated elements to maintain compartmentation.
 
EN 1364-4 testing is the primary route for compliance for testing fire stops in horizontal orientation in combination with curtain wall facades. When testing to EN 1364-4 in combination with 'Type A' non-fire rated curtain walls it is necessary to protect the spandrel zone with Siderise CW-FB. ‘Type A’ is the most common type of curtain wall in the UK. Please see  our public website for EN 1364-4 tested arrangements and standard details.
 
EN 1364-4 testing has been undertaken on a curtain wall system incorporating CW-FS120 in accordance with EAD 350141-00-1106, including horizontal movement cycling to 500 times (±10% of void width) pre-test (UL Test 4789510602-1, Oct 2021).
 
Following the route set out in the EAD for horizontal movement cycling pre-test followed by testing to EN 1364-4 is the most demanding and relevant way of assessing the performance of firestops for commercially available ‘Type A’ curtain walls.
 
CW-FS has also been tested in isolation to EN 1366-4 in both horizontal and vertical orientations.
 
Approved Document B (England & Wales)
 
Approved Document B for England & Wales (2019 edition) gives classification to EN 13501-2 as the primary route to compliance via EN 1364-4 testing for fire stops in curtain wall systems in a horizontal orientation.
 
EN 1366-4 testing is also available for Siderise CW in isolation of the curtain wall, where Siderise CW-FS is tested between two leaves of concrete. This standard is applicable to firestops tested for curtain wall applications in a vertical orientation. EN 1366-4 is also applicable for non-curtain wall applications in both horizontal and vertical orientations.
 
For any voids not covered by Tables 2-4, please contact technical.services@siderise.com for advice on these options.
 
Third-Party Certification
 
CE Marking (Cert No. 2531-CPR-CXO10200) has been achieved based on ETA 21/0297 in accordance with EAD 350141-00-1106, which can also be downloaded from our online technical resources.
 
Certifire certification (CF 563) has been achieved, based on proven fire performance, for horizontal applications to EN 1364-4 (Table 2), and horizontal and vertical applications to EN 1366-4 (Table 3 & 4).
 
'Certifire certification and any product label is only applicable to the specific scope and field of application as defined within the current and valid Certifire certificate number CF563. Any additional details, amendments or additions to the product, or any use outside the scope or field of application, outside of that stated within certificate number CF563 has not been reviewed or approved by Warringtonfire.'
 
IFC certification (IFCC 1763) has also been achieved, based on proven fire performance for horizontal and vertical applications to EN 1366-4 (Table 3 &4).
 
Intertek certification (WHI19-32944301) has also been achieved, based on proven fire performance for horizontal applications to EN 1364-4(Table 2).
For further details on all Third Party Certification, the certificates can be downloaded from our online technical resources or from the certification body

Table 2: Fire Resistance to EN 1364-4 (Horizontal Orientation for Curtain Walls)

Void Width (mm) Product Ref. Product Thickness Compression
(minimum)** 
Integrity
( mins) 
Insulation
(mins) 
Cover
Length
(mm) 
Bracket Requirement* 3rd Party Approvals 
20 to 50 CW-FS120 120mm +10% 120 120 1200 2no.B65/110
600mm centres 
Certifire CF 563
Intertek WHI19-32944301 
 CW-FS180 150mm +10% 180 180 1200 2no.B65/110
600mm centres 
Certifire CF 563
Intertek WHI19-32944301 
51 to 150 CW-FS120 120mm +10% 120 120 1200 2no.B65/110
600mm centres 
Certifire CF 563
Intertek WHI19-32944301 
 CW-FS180 150mm +10% 180 180 1200 2no.B65/110
600mm centres 
Certifire CF 563
Intertek WHI19-32944301 
151 to 250 CW-FS120 120mm +10% 120 120 1200 2no.B195
600mm centres 
Certifire CF 563
Intertek WHI19-32944301 
 CW-FS180 150mm +10% 180 180 1200 2no.B195
600mm centres 
Certifire CF 563
Intertek WHI19-32944301 

*All fixing brackets are to be mechanically fixed to the structure. Please see the installation instructions.

**Façade deflection should be taken into consideration with respect to installation compression, please see ‘Movement Characteristics’.

Table 3: Fire Resistance to EN 1366-4 (Horizontal Orientation For Non-Curtain Wall Applications)

Void Width (mm) Product Ref. Product Thickness
(mm) 
Compression (minimum)** Integrity
(mins) 
Insulation
(mins) 
Cover
Length
(mm) 
Bracket Requirement* 3rdParty Approvals 
20 to 50 CW-CB30 75 +10% 60 30 1200 None Certifire‘CF 563’
& IFCC 1763 
 CW-FS60 90 +10% 90 60 1200 None Certifire‘CF 563’
& IFCC 1763 
 CW-FS120 120 +10% 120 120 1200 None Certifire‘CF 563’
& IFCC 1763 
51 to 150 CW-CB30 75 +10% 60 30 1200 2no.B65/110
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS60 90 +10% 90 60 1200 2no.B65/110
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS120 120 +10% 120 120 1200 2no.B65/110
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
151 to 240 CW-CB30 75 +10% 60 30 1200 2no.B195
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS60 90 +10% 90 60 1200 2no.B195
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS120 120 +10% 120 120 1200 2no.B195
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
241 to 300 CW-CB30 75 +10% 60 30 1200 2no.B355
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS60 90 +10% 90 60 1200 2no.B355
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS120 120 +10% 120 120 1200 2no.B355
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
301 to 350 CW-CB30 75 +10% 60 30 1200 2no.B355
600mm centres 
IFCC 1763 
 CW-FS120 120 +10% 120 120 1200 2no.B355
600mm centres 
IFCC 1763 
301 to 600 CW-FS60-X 120 +20mm 60 60 1200 2no.B355
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
*All fixing brackets are to be mechanically fixed to the structure. Please see the installation instructions.

**Façade deflection should be taken into consideration with respect to installation compression, please see ‘Movement Characteristics’.

Table 4: Fire Resistance to EN 1366-4 (Vertical Orientation)*

Void Width (mm) Product Ref . Product Thickness
(mm) 
Compression (minimum)*** Integrity
(mins) 
Insulation
(mins) 
Cover
Length
(mm) 
Bracket Requirement** 3rdParty Approvals 
20 to 50 CW-CB30 75 +10% 90 30 1200 None Certifire‘CF 563’
& IFCC 1763 
 CW-FS60 90 +10% 90 60 1200 None Certifire‘CF 563’
& IFCC 1763 
 CW-FS120 120 +10% 120 120 1200 None Certifire‘CF 563’
& IFCC 1763 
51 to 150 CW-CB30 75 +10% 90 30 1200 2 no. B65/110
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS60 90 +10% 90 60 1200 2 no. B65/110
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS120 120 +10% 120 120 1200 2 no. B65/110
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
151 to 240 CW-CB30 75 +10% 90 30 1200 2 no. B195
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS60 90 +10% 90 60 1200 2 no. B195
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS120 120 +10% 120 120 1200 2 no. B195
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
241 to 300 CW-CB30 75 +10% 90 30 1200 2 no. B355
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS60 90 +10% 90 60 1200 2 no. B355
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS120 120 +10% 120 120 1200 2 no. B355
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
301 to 450 CW-CB30 75 +10% 90 30 1200 2 no. B355
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS60 90 +10% 90 60 1200 2 no. B355
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
 CW-FS120 120 +10% 120 120 1200 2 no. B355
600mm centres 
Certifire‘CF 563’
& IFCC 1763 
451 to 600 CW-FS60-X 120 +20mm 60 60 1200 2 no. B355
600mm centres 
Certifire‘CF 563’
& IFCC 1763 

*For vertical firestop applications to the end of a flexible wall (e.g. stud partitions), please consult technical.services@siderise.com for advice on appropriate product selection and application.

**All fixing brackets are to be mechanically fixed to the structure. Please see the installation instructions.

***Façade deflection should be taken into consideration with respect to installation compression, please see ‘Movement Characteristics’.

Acoustic Performance

Additionally, the CW-FS range of barriers are acoustically absorptive. 

Furthermore, the foil facings and the additional sealing of joints with Siderise foil tape all serve to provide improved airtightness.

Sound reduction between floors

The installation of the CW systems within an external curtain wall cavity can increase the floor-to-floor attenuation.

The acoustic flanking performance of a curtain wall detail will depend on the specifics of the construction. When incorporated between mass lines that close the slab-edge void, such as the Siderise AB10 overlay and CVB/C-10 cavity barrier, the CW-FS range can provide an absorptive layer which can increase the overall acoustic performance of the detail.

Table 5 confirms the laboratory tested values for Weighted Sound Reduction Index (dB Rw) in accordance with BS EN ISO 140-3: 1995, BS 2750 Pt 3: 1995.

Table 5: CW acoustic performance

 Weighted Sound Reduction Index 
Product Type Thickness (mm) Rw (dB) 
CW-CB30 75 21 
CW-FS60 90 22 
CW-FS120 120 25 

Siderise offers a range of complementary acoustic mass overlay materials which can further enhance the overall acoustic performance of the construction.

The Siderise AB10 is a flexible acoustic membrane for use as a mass-barrier above Siderise CW-FS fire stops in curtain walls. Using this acoustic upgrade offers an improvement to the acoustic performance of the firestop. Incorporating mass barriers such as the Siderise AB10 into slab-edge details can assist with controlling floor-to-floor sound transmission.

 

Siderise AB10 is quick and easy to install, and is suitable for use in all curtain walls. The product is thin and flexible, and is designed to accommodate façade movement, unlike traditional mass-barrier materials such as steel or plasterboard.


As the AB10 is sold as an acoustic upgrade for our CW-FS firestops, we have not tested its standalone performance. However, for the purposes of assessment by project acoustic consultants, the Weighted Sound Reduction index (dB Rw) of the mass barrier layer alone is presented below(Table 6).

Table 6: AB acoustic performance

 Weighted Sound Reduction Index 
Product Type Surface mass(mm) Rw(dB) 
AB10 10 kg/m2 28 

Table 7: CW-FS, CW-AB and CVB/C acoustic performance

Product 21 - 30dB R  31 – 35dB R  36 - 50dB R  50dB Rw  
RRw + Ctr Rw Rw + Ctr RRw + Ctr RRw + Ctr 
SIDERISE CW-FS60 23 21 
SIDERISE CW-FS120 25 23 
SIDERISE CW-FS120 + AB10 Overlay 37 32 
SIDERISE CW-FS120 + AB10 Overlay + CVB/C10 below 51 45 
SIDERISE CW-FS120 + 2mm Steel Plate Overlay + CVB/ C10/75 below 53 45 
The table above illustrates typical acoustic performance of CW-FS, CW-AB and CVB/C products when used in an arrangement, please see our website for individual product information and standard details. Please note that the values presented in the above table refer to the standalone performance of Siderise products only. For full system performance requirements given as a DnT,w or Dn,f,w value, Contact our facades technical team at technical.services@siderise.com for performance guidance.

Thermal Performance

Thermal conductivity: λ = 0.038 W/m.K ±5% (tested foil to foil) to EN 12667: 2001

Technical Specification

Siderise Perimeter Barriers Fire stops for Curtain Walling and Weathertight Façade Systems


Table 8: Product Properties

Form Supplied Sheets : 1200mm x 1200mm (UK and EU); 1200mm x 1100mm (RoW): Thickness is denoted by the rating
Pre-cut strips : 1200mm x (void width + compression) x thickness, please see tables 2-4 
Colour Solid, green-brown exposed edges with silver aluminium top and bottom facings 
Finish Aluminium foil 
Density Nominal 75 kg/m3 
Thermal Conductivity λ = 0.038 W/m.K ±5% (tested foil to foil) to EN 12667: 2001 
Void width 20mm to 600mm
Please see tables 2-4 
Reaction to fire EN 13501-1 : Class ‘A1’ 
Resistance to fire 30 to 180 minutes, please see tables 2-4 
Water Vapour Absorption <5% by weight to ASTM C1104-19 (with foil facing removed). This meets the standard specification for ‘Mineral Fibre Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing’ ASTM C C665-17, clause 7.5 
Fungi Resistance When tested to ASTM C1338-19 no fungal growth was observed after 28 days 
Movement Characteristics-Curtain walling and external facade deflection

For curtain walling applications it is imperative that the installed firestop can function effectively with due regard to all designed movement serviceability limits.

Siderise recognises that curtain walling and cladding façade systems will deflect due to:

  • Positive wind-load
  • Negative wind-load
  • Occupational live load

The above are covered by EN 13116:2001.

Typically, a project may stipulate that the curtain walling system may have the following allowable deflection limits:
 
Under the declared wind loads the maximum frontal deflection of the curtain walling framing members shall not exceed L/200 or 15mm, whichever is the less, when; measured between the points of support or anchorage to the building structure in compliance with EN 13116. [Extract from EN 13830]

For vertical applications where the façade deflection may be up to 15mm, we recommend that you calculate the design deflection of the external façade system in both positive and negative wind load situations. Then follow Tables 2 to 4 + the additional design deflection of the system if required. Additional material allowances should be included whenever façade deflection is anticipated beyond the product compression requirement. For example with a maximum expected façade deflection of 15mm:
 
Void Width + 10% Compression + Facade Deflection
For 180mm void = 180mm +18mm + 15mm  =  213mm of CW-CB/ CW-FS
Where the required compression of the firestop is greater than 10%, we suggest trialing the installation on-site to ensure it can be installed, as feasibility will vary depending on the void width.
 
These factors may inevitably combine to preclude the suitability and therefore, use of certain other systems e.g. high-density material slab products.
 
However, the CW-FS fire stop systems are remarkably effective for their function within curtain walling as the unique material construction can accept the cyclical negative and positive wind and live loads imposed on the façade.

Table 9: Physical Characteristics

Characteristic Value 
Manufacturer and Product Name Siderise CW-FS 
Product Type Perimeter Barriers and Firestops for Curtain Walling 
Code/Model/Reference/SKU CW-FS 
Description See 'Product Description' section 
Application/Use See 'Application' section 
Material See Safety Data Sheet section 3.1 
Weight Precut strips - Max Carton Weight 30kg ; Full individual sheets from 8.3 +/- 0.1 kg to approx 13.7+/- 0.4 kg (75mm to 120mm thick respectively) 
Finish /Colour Solid, green-brown exposed edges with silver aluminium top and bottom facings 
Packaging Pre-cut strips packaged in cardboard cartons size; Full sheets packaged on pallets 
Pack Size Pre-cut strips packaged in cardboard cartons size up to 1230mm x 610mm,
Full sheets packaged on pallets 1210mm x 1210mm 
Unit of measure millimetre (mm) 
Chemical properties/Safety data sheets See Safety Data Sheet section 3.1 
Size/dimensions (product & installation spatial requirement) See Table 8 'Form Supplied' 
Shelf life n/a;
Store in dry conditions and protect from mechanical damage. 

Environmental

  • The stonewool core is recyclable

Additional Information

The following information is available upon request or via download from the website:

  • Third-Party Certification
  • Safety Data Sheet
  • Product Brochure
  • Standard Details
  • Installation Instructions
  • Installation Video
  • NBS Specification Clauses

Technical Support

For technical advice or support please contact: technical.services@siderise.com

For Installation Training or Site Inspections please contact: site.services@siderise.com

Context

The information in this datasheet is believed to be accurate at the date of publication. Siderise has a policy of continuous product improvement and reserves the right to alter or amend the specifications of products without prior notice. Siderise does not accept responsibility for the consequences of using the products described outside of the recommendations within this datasheet. Expert advice should be sought where there is any doubt about the correct specification or installation of Siderise products.

 
 
Published Version: CW_v2_04_2023105_1939